Society in progress, science and technology bring people more and more convenient and comfortable, integrated kitchen is such result, while protect our smokeless kitchen mute life time of happiness, integrated set of lampblack machine, kitchen burning gas oven, disinfection cabinet is equal to one, powerful are popular with consumers, but integrated kitchen will fail, destroying our use of perception, then you know what caused by the integrated fault of the oven is? How to solve it?
Integrated oven flame section
 
 
Q: why is it difficult to integrate environmentally friendly stove ignition?
 
 
Answer: ignition knob did not turn 90 degrees, the air outlet is too small, the gas through not much, can not burn normally, the correct operation of the rotary ignition knob in place; Spark ignition weak, replace the battery; If the gas path is not unobstructed, check whether the gas path between the gas main and the gas branch pipe is unobstructed and whether the nozzle is blocked; Fire cover fire groove is not aligned with the fire needle, rotating aluminum cover can be aligned; Fire cover kindling plug, clean kindling plug; More air is mixed in the air pipe, so the ignition time should be prolonged until the air in the pipe is completely discharged. Ignition electrode oxidation, can use dry cloth to clean; Bend or flatten metal hose. After straightening metal hose, check for air leak.
 
 
Two ask: why integration environmental protection stove after ignition often automatic flameout?
 
 
Answer: thermocouple (ion detection needle) position without flame, correction; Thermocouple parts of the fire is not normal, debugging the inner fire ring damper; Pulse igniter or solenoid valve damage, detection and replacement.
 
 
Three ask: why integration environmental protection stove flame not good?
 
 
Answer: the air circuit is not unobstructed. The air circuit between the gas main pipe and the gas branch pipe is unobstructed. Please check whether the nozzle is blocked. Replace the gas if it is of poor quality or at the bottom of the bottle.
 
 
The combustor is damp, which is normal after natural drying; Fire hole plug, clean up the fire hole plug; If the fire cover and aluminum cover are not in place, put the fire cover into the locating pin; The damper is not properly adjusted. Adjust the damper to optimize the flame.
 
 
Four ask: why integration environmental protection stove fire sound unusual?
 
 
Answer: the quality of gas is poor or the bottom of the bottle gas, to replace the gas; Fire hole plug, clean up the fire hole plug; If the fire cover and aluminum cover are not in place, put the fire cover into the locating pin; The damper is not properly adjusted. Adjust the damper to optimize the flame.
 
 
Integrated kitchen function
 
 
Q: why is the integrated environmental protection kitchen screen not bright?
 
 
Answer: if the power cord falls off or the protection plug is damaged, please refer to the wiring diagram for repair or replacement after checking and judging; Power board or computer board damage, check and judge, repair or replace.
 
 
Q: why does the integrated environmental protection kitchen disinfection cabinet not work?
 
 
Answer: power board or computer board damage, check and judge, repair or replacement; 2, the cupboard door is not closed or deformation, close the cupboard door or cupboard door magnetic sealing strip reshaped; The door switch is damaged. Replace it.
 
 
Seven q: why the integrated environmental protection cooker induction cooker work is not normal?
 
 
Answer: the POTS and pans do not meet the requirements directly. Please use the POTS and pans correctly according to the instructions. The bottom of the pot is not flat, replace the flat bottom of the pot; Place position to deviate a center, boiler provides place center of pottery and porcelain plate to be able to.
 
 
Integrated kitchen fan
 
 
Q: why is there abnormal sound in operation of integrated environmental protection stove fan?
 
 
A: the impeller is loose, not fastened, and the lock nut is screwed.
 
 
Q: why does the integrated environmental protection stove fan not work?
 
 
Answer: if the power cord falls off or the protection plug is damaged, please refer to the wiring diagram for repair or replacement after checking and judging; Power board or computer board damage, check and judge, repair or replace; If the temperature of the motor rises above 125 degrees, it can return to normal after cooling. It may be that the motor is burnt out and needs to be replaced. Control line connection plug contact is poor, refer to the circuit connection diagram to check the plug, to ensure good contact; The capacitor is damaged and needs to be replaced.

News


【Haobao, Haoni Tan Guangjiao】Explore intelligent technology with you and enjoy the quality of life

Zhejiang Shengzhou Jilu Ventilation Equipment Co., Ltd. shows global buyers and overseas social media fans of the Canton Fair powerful and portable electronic new products with a clever combination of technology and aesthetics!


Integrated kitchen knowledge solution, fault repair is no problem

Society in progress, science and technology bring people more and more convenient and comfortable, integrated kitchen is such result, while protect our smokeless kitchen mute life time of happiness, i


Happy New Year to you all!

Spring send hi, wish you happy often accompanied by peace, want to be together, often get your wish, money in the side, more happy days, happy more perfect, harmony in the year of the pig, everything


The market of kitchen and bathroom has been upgraded to a "new favorite" in the industry.

Times change and markets change. What changes have taken place in the kitchen and bathroom market in 2017? He who knows his own enemy, will be victorious. Under the new situation, how should enterpris